TC06-70ZEH/01,700W DC48V Door Mounted Cabinet Air Conditioner, For Outdoor Telecom Cabinet

Place of Origin : China
Brand Name : ESTEL
Certification : ISO9001:2008
Model Number : TC06-70ZEH/01
MOQ : 1 Set
Packaging Details : Wooden Case
Delivery Time : 15 days
Payment Terms : T/T
Supply Ability : 30000 Sets Per Year
Contact Now

700W DC48V AIR CONDITIONER

Model: TC06-70ZEH/01

1. Introduction

The TC06-70ZEH/01 air conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information. The product is widely applied in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
2. Features
(1)Strong adaptability
(2)High intelligence
(3)High precision
(4)High reliability
(5)Low noise
(6)Low energy consumption
(7)With 4 way switching value detection
(8)With 1 way room air conditioner control
(9)Wide input voltage range: 48VDC±15%
(10)With dry contact alarm output

3. System Principle Diagram

Diagram 1: System Principle Diagram


4. Standard Compliance

Standard

Description

GB/T 17626.7-1998

Electromagnetic compatibility

GB4706.1

Safety of household appliance and electrical appliance with similar use.

GB4798.1

Environmental conditions existing in the application for electric and electronic products - storage

GB4798.2

Environmental conditions existing in the application for electric and electronic products - transportation

GB4798.3

Environmental conditions existing in the application for electric and electronic products - usage

 
5. Technical Parameters

Model No.

TC06-70ZEH/01

Environmental Performance

working environmental temperature

-20°C ~ 55°C

storage working temperature

-50°C ~ 70°C

working humidity

≤95%

Thermal Performance

rated cooling capacity

780W(L35 L35)

700W(L25 L35)

heating input power

no


Electrical Performance

rated input current

3.6A(L35 L35)

3.4A(L25 L35)

rated input power

172W(L35 L35)

163W(L25 L35)

input voltage

DC48V

Reliability

MTBF

60000 hours

Noise

≤65dB

Diagram 2: Dimension Diagram

6. Electrical Wiring Diagram

Diagram 3: Wiring Diagram
Wiring Ports:
0V -48V: power supply input (voltage input: 48VDC±15%)
F+ F- : direct ventilation output
AL1 AL2: general alarm output
TX RX SGND: communication interface
N: not connected pin
7. After mechanical installation and electrical installation are finished, check the installation items.
(1)Make sure the air conditioner is firmly installed.
(2)Check the electrical installation circuit, and ensure it doesn’t have short circuit.
(3)Check the air outlet, air inlet, internal fan and external fan of the air conditioner, and ensure they don’t have any odds and ends.
Connect the air conditioner to power supply, and test the power supply (voltage input: 48VDC±15%), operating current 3.5A±4%.
8. System Control
Terminology:
BTH: Temperature & Humidity of Box;
ETH: Temperature & Humidity of Engine Room;
BAC: Box Air Conditioning;
CAC: Cabinets Air Conditioning;
BACS: Box Air Conditioning Start Times;
BACR: Box Air Conditioning Run Time;
CACS: Cabinets Air Conditioning Start Times;
CACR: Cabinets Air Condintioning Run Time;
VP Temp.: Vent-pipe Temperature;
AC FSV: Air Conditioning Value of Current;
CPar: Parameter of Control;
BPar: Parameter of Base;
A/M: Automatic / Manual;
MaxTemp: Maximum Temperature;
MixTemp: Minimum Temperature.
8.1 Application
ET872 thermostatic battery cabinet controller is a type of universal intelligent controller. It is controlled by highly integrated STC single chip microcomputer. It can intelligently control operating and hydrogen exhaust of thermostatic cabinet air conditioner, and can control a telecom room air conditioner. It have the following functions: fault self diagnosis, power on self start, restart after unexpected failures caused by other reasons.
The controller features perfect performance, easy and fast installation and setting, which is widely used in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
8.2 Main Technical Parameters
a.2×16 Chinese/English shift LCD display, user friendly;
b.Simultaneously display temperature and humidity inside the box and communication room temperature;
c.Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:4%;
d.Can store 180 days’ daily event record, 1 record every day;
Daily highest temperature, lowest temperature, average temperature
Daily event record;
e.Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
f.RS485 or RS232 communication,RTU-Modbus protocol, support remote detection and control;
g.Use PID control algorithm, intelligently adjust output power, optimize energy efficiency;
h.Controllable air conditioner quantity: 2 sets. 1 set of air conditioner for communication room, and 1 set of air conditioner for thermostatic cabinet.
i.Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner);
j.Real-time control air conditioner on/off
k.Power supply: DC48V;
l.Power consumption:≤5W;
m.Working environment: -30°C~70°C; <90%RH;
n.Installation method: guide rail,hanging;
o.Dimension(L*W*H):150mm×190mm×45mm
8.3 Operating Instruction
ET872 uses user-friendly interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:
Diagram 4 Control Board Diagram
8.3.1 Buttons
PgDn:page down button, confirm button.
Press once and release the button, page down;
A long press on the button, enter or exit parameter status;
At operating status: can select five display interfaces;
At parameter status: revise, confirm and parameter page down button; a long press on the button to exit parameter status.
▲:increasing parameter revision. Page down button for event query.
▼:decreasing parameter revision. Page up button for event query.
PgUp: page up button; the function is oppose to PgDn operation.
8.3.2 Indicators
When the air conditioner works normally, the Work indicator flashes at 2s frequency, showing it is working normally. When there is screen saver, the indicator can indicate the system is working normally.
When the system has alarm, the Alarm indicator will turn on, showing alarm occurs.
8.3.3 Operating Interfaces
The controller includes three working modes: operating mode, parameter mode, and query mode.
(1) Operating Mode:
The mode is normal working mode. There are five operating interfaces which can be selected. The five interfaces display different content. When they are not selected, the interfaces will automatically shift. Press the button “PgDn” to select next display interface; press the button “PgUp” to select the previous display interface.
Interface 1:
Line 1: temperature and humidity inside the thermostatic box (or area I);
Line 2: temperature and humidity inside communication room (or area II);
Diagram 4 is the first interface (main interface) of this mode.
Interface 2:
Line 1: control status indication. Separated by the sign “/”, the former is box air conditioner status: “OFF” means compressor and heater both stop; “30%-100%” means compressor output percentage; “¤” means heater are working; “♂” means hydrogen exhaust or direct ventilation. The latter is cabinet air conditioner status: “Off” means stop; the first “*” means cabinet air conditioner control; the second “*” or “>” is actual status, means the air conditioner is at cooling status; If it display “>”, it means the air conditioner only blow air.
Line 2: real time, manual/auto status. “Auto” means auto status, “Menu” means manual status.
At manual mode of this interface, press buttons “▲,▼” can manually increase or reduce control output of box air conditioner, and the control output of fan will increase or reduce synchronously.
Interface 3:
Display real rotational speed of inner fan and outer fan.
At manual mode of this interface, press buttons “▲,▼” can manually turn on/off control output of cabinet air conditioner.
Interface 4:
Display temperature of inner coil and outer coil.
At manual mode of this interface, press buttons “▲,▼” can manually turn on/off control output of hydrogen exhaust.
Interface 5:
Circularly display current alarms;
When multiple alarms occur, it will display each alarm information circularly.
(2)Parameter Mode:
At operating status, long press on the button ”PgDn” for around 3 seconds, or press the button ”PgUp” at interface 1, to enter parameter mode.The first entered interface is the main menu interface, see the following diagram.
Press the button “▲”, “▼” to choose corresponding parameter group; Press ”PgDn” to enter corresponding parameter group; Press ”PgUp” to return to operating mode. The parameters selection includes:
(a) Observation Parameter
(b) Control Parameter Revision
(c) Basic Parameter Revision
(d) Manual/Auto Selection
(e) Event Query
(f) Return To Operating Mode
(a)Observation Parameter Group (Apar):
Enter the interface to check some parameters which can’t be checked at operating mode, see “8.3.4 Parameter Instruction”.
At parameter mode: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
(b) Control Parameter Group (CPar):
Enter the interface to observe or revise the parameters which can be revised, see “8.3.4 Parameter Instruction”.
At parameter mode: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
(c) Basic Parameter Group (BPar):
Enter the interface to observe or revise the parameters which can be revised, see “8.3.4 Parameter Instruction”.
At parameter mode: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
(d) Manual Operation Parameter Group (A/M):
Enter the interface to select “Cool”, “Heater”, “Air”, “ToAuto” to conduct manual start and stop operation.
(e) Event Query (Query):
Enter query mode
8.4 Wiring Diagram
Diagram 4: Inner Terminals Wiring Diagram
JD1: main power supply input (DC48V);
JD2: heating control output;
JD4: fan control port:
1- 48V; 2- inner fan control; 3- inner fan feedback;
4- outer fan control; 5- outer fan feedback; 6- 0V.
JD5: direct ventilation (hydrogen exhaust) output port (48V);
JD6: DC compressor control port:
connected with compressor control board control port. Please note the direction.
JD7: alarm ouput port:
1, 2: general alarm output dry contact;
3, 4: air conditioner system alarm output.
JD8:
1, 2: remote control dry contact input;
3, 4: working status output dry contact;
JD9: communication port:
1: RXD (or 485A+); 2: TXD (or RS485B-); 3: SGND;
JD10: connected with four DI input.

China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

TC06-70ZEH/01,700W DC48V Door Mounted Cabinet Air Conditioner, For Outdoor Telecom Cabinet Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0