Sign In | Join Free | My splicd.com
splicd.com
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Home > One Compartment Outdoor Telecom Cabinet >

Flexible Assembly Energy Saving Outdoor Telecom Cabinet, Used For Outdoor Various Weathers, Anti-corrosion Powder Coatin

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Country/Region: China
Tel: 86--13752765943
Contact Person:
Ms Fiona Liang

Flexible Assembly Energy Saving Outdoor Telecom Cabinet, Used For Outdoor Various Weathers, Anti-corrosion Powder Coatin

Brand Name : ESTEL
Model Number : ET9090210-110V60HZ
Certification : ISO9001:2008
Place of Origin : China
MOQ : 1 Set
Price : negotiation
Payment Terms : T/T
Supply Ability : 8500 Sets Per Year
Delivery Time : 15~20 Days
Packaging Details : Wooden Case
External Dimension : W×D×H 900×900×2100mm
Internal Dimension : W×D×H 800×800×1800mm
Cabinet Layout : one compartment, for installing 19” power equipment
Protection Level : IP55
Material : galvanized steel (aluminum, stainless steel)
Grade B Lightning proof : Nominal: 60KA, Max.: 100KA
Color : grey (support custom made,such as green etc)
Coating : anti-corrosion outdoor powder coating
Structure : double wall, with insulation, sandwich structure
Cabinet Lock : anti-theft three point lock
Cable Entry : at cabinet bottom
Grounding Protection : copper bar
Cooling Method : AC110V 60Hz air conditioner and DC48V fans
Accessories Options : Accessories Options: PDU, environment monitoring system
Lighting : 48V LED lamps (immovable), with protective circuit breaker
Relative Humidity : 5% ~ 100%
Working Temperature : -40°C ~ +55°C
Contact Now

Flexible Assembly Energy Saving Outdoor Telecom Cabinet, Used For Outdoor Various Weathers, Anti-corrosion Powder Coating



1. Applications


The Outdoor Telecom Cabinet, made from metallic material or non-metallic material, can be used under various weathers and climates, providing outdoor physical work environment and safety system for wireless telecom station or wired network station. Operators without permission are not allowed to get access to the cabinet.

The cabinet is suitable for outdoor environment, such as road side, park, building roof, mountain area, flat ground, etc. The cabinet can be installed with base station equipments, power supply equipments, batteries, temperature control equipments, transmission equipments and other equipments, or the cabinet can reserve installation space and heat exchange capacity for the above equipments, providing reliable mechanical and environmental protection for normal operation of the internal equipments.


2.Features


ESTEL’s Energy Saving Integrated Cabinet provides complete solutions for outdoor working environment and safety management of telecom base station. As a base station, it can integrate the main equipments, system power supply, AC and DC power distribution, environment monitoring, batteries, lightning protection and grounding devices. As functional cabinet (battery cabinet, power supply cabinet, transmission cabinet etc.), it can help telecom carriers to realize easy station obtaining, energy saving, fast deployment.


The cabinet is weatherproof, such as sun-proof, dust-proof and rainproof, which is used in outdoor environment.


Cabinet cooling: air conditioner and auxiliary direct ventilation fans. MTBF≥50000h.


Cabinet load bearing: ≥600kg


Ingress protection: IP55


The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There are entrance holes individually for power cable, signal cable and optical cable.


All the cables used in the cabinet are made from flame retardant materials.


The cabinet includes grounding bar.


Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.


Flame retardance: comply with GB5169.7 test A


Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).


Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.


Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.



3. Advantages


(1)Flexible structure


Compartment type design


Flexible assembly


Single compartment


(2)Standard compartment temperature control


Multiple temperature control modes optional


High efficiency and energy saving


(3)High integrated


High compatibility, high integration


Supporting multiple equipments, good appearance


(4) Fast deployed


Can be assembled, easy for transportation


Modular assembly, short installation time


4. Specifications


(1) Technical Parameters


ItemTypeTechnical Parameter
StructureDimension

External Dimension: W×D×H 900×900×2100mm

Internal Dimension: W×D×H 800×800×1800mm

Layout1 compartment
Equipment Installation Method19” rack
DoorWith one front door, and anti-theft three point lock for outdoor cabinet (support padlock)
MaterialGalvanized steel, sandwich structure with double wall and heat insulation
Heat InsulationThere are heat insulation between inner wall and outer wall.
Ingress ProtectionIP55
Temperature ControlCoolingAC110V 60Hz air conditioner and DC48V fans
Lightning ProofGrade B lightning proofNominal: 60KA, Max.: 100KA
LightingLED lamp48V LED lamps (immovable), with protective circuit breaker
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1120 ×(1±5%)W/m2

(2) Configuration List

No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension:W×D×H 900×900×2100mm

Internal Dimension: W×D×H

800×800×1800mm

(2) One compartment: equipment compartment

(3)With one front door, and anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material

(4.1) Cabinet left side, right side and back: sandwich structure panel, outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS.

(4.2) Cabinet door and base: outer plate: 1.5mm galvanized steel , inner plate: 0.8mm galvanized steel, insulation: 40mm PEF.

(4.3) Cabinet roof: sandwich structure panel (outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS. ) + 1.0mm galvanized steel.

2Air Conditioner1Set

Cooling capacity: 1.5KW,

Power supply: AC110V, 60HZ,

Model:TC06-150JFH/01

3Auxiliary Direct Ventilation Fans2PCDC48V
4Environment Monitoring Unit1Set19", 1U; Model: SM2400, Power Supply: AC110V Including utility power alarm function
5Water Sensor1PC
6Smoke Sensor1PC
7Temperature and Humidity Sensor1PC
8Door Sensor2PCOne for controlling LED lamp, the other for open door alarm
9LED Lamp1PCDC48V
10Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4

Input Voltage: AC110V.

11Package1SetWooden Case


Drawing:




5. Description


5.1 Components Installation


LED lamp, LED lamp sensor, smoke sensor and door sensor are installed at the top of the cabinet. Environment monitoring unit and PDU are installed on 19” rack. Water sensor is installed at the bottom of the cabinet.Temperature and humidity sensor is installed at the side inside the cabinet. Air Conditioner and fans are installed on the door of the cabinet.







5. 2 Cable Inlet


Feeder cable and other external cables all use bottom wiring method.



5.3 Grounding Protection


(1)The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.


(2)The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.


(3) Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.



5.4 Door lock theft proof design


Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.



Three point lock



5.5 Connection and Fastening


(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.


(2) Door hinges use inner hinge mode.



5.6 Appearance and Surface Treatment


Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.


6. Packing




China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Flexible Assembly Energy Saving Outdoor Telecom Cabinet, Used For Outdoor Various Weathers, Anti-corrosion Powder Coatin Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Subject:
Message:
Characters Remaining: (0/3000)
 